Redox Meter

Redox Meter

with test leads, holster, manual and 9V battery (installed).

CodeSL369
Approx. Weight (kg)0.55
Tariff382200 00 0
Click to save page as PDF Save Page to PDF
addthis
or
Call Impact +44 (0)1294 602626

The SL369 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap.
For probes see SL370 and SL371

Features

  • Resistance, continuity, frequency, capacitance & diode test.
  • Measures 20 A (30 seconds momentary; 10 A continuous).
  • Large white LED backlight to work in poorly lit areas.
  • Compact ergonomic design for one-handed operation.
  • Compatible with optional magnetic hanger (ToolPak).
  • True-rms for accurate measurements on non-linear loads.
  • Min / Max / Average with elapsed time to record signal fluctuations.
  • CAT III 600 V safety rated.
  • Display: 6,000 counts, updates 4/sec.
  • Dimensions: (HxWxD): 167 x 84 x 46mm.
  • Weight: 0.55kg (including batteries).
  • Warranty: 3 year.
Specification
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight
Accuracy Specifications

DC millivolts

Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2

DC volts

Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2

AC millivolts1 true-rms

Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)

AC volts1 true-rms

Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)

Continuity

Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.

Ohms

Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5 % + 2

Diode Test

Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2

Capacitance

Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%

Lo-Z Capacitance

Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical

AC amps true-rms (45 Hz to 500Hz)

Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30-seconds max

DC amps

Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30-seconds max

Hz (V or A input)2

Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2

Notes:

  1. All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
  2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
  3. Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
  4. Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
  5. Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
General Specifications
Dimensions 167 x 84 x 46 mm
Weight 550g
Warranty 3 years